This article is about the original SmartCap hardware. For Life by SmartCap hardware, please go to Life by SmartCap.
This setting is only relevant when connecting the SmartCap Display to something other than a base unit or SmartCap compatible 3G/4G modem. It is possible to change the serial connection speed of the SmartCap Display if the device connected to the SmartCap Display is not able to run at 115200 Bd.
STEP 1: Go to MENU > ADVANCED > CONFIG > COM SPEED
STEP 2: Use the two arrows on the bottom of the screen to cycle through the available COM speeds:115200 [default]
57600
38400
19200
9600
4800
2400
STEP 3: Press the SET button to enable the new COM speed
STEP 4: Reset the display to apply the new COM speed